Ex 防爆标志
Zone 1&2
IP 防护标识
+
  • KXD51.webp
  • KXD51-3.webp
  • KXD51-4.webp

Explosion-proof Distribution Device

KXD51 Series


• Explosion protection to - CENELEC - IEC - NEC • Can be used in - Zone 1 and Zone 2 - Zone 21 and Zone 22 - Class I, Zone 1 and Zone 2 - Class I, Division 1, Groups B, C, D

Category:

Explosion-proof Distribution Device

  • 产品描述
  • CATALOG NUMBER LOGIC

     

    FEATURES

    • Flameproof enclosure (Ex d IIB+H2), which can be used as feed distribution equipment in control and distribution system(such as distribution box, switch box of main circuit ,control box, terminal box or motor starting box etc.)
    • Copper-free Aluminium Alloy enclosure, powder coated surface.
    • Equipped with specialized hinge structure, which can prevent the flameproof joints from damage when opening and closing the panels, and greatly prolong the service life of box.
    • The boxes can be combined and installed freely to save space and meet the requirements of various distribution systems.
    • Special requirements on request.

     

    Application sectors

     

    TECHNICAL DATA

    Explosion-proof Distribution Device  KXD51 - □ / □ / □ / □

    Ex-mark (IECEx)

    Ex db IIB+H2 T□1) Gb
    Ex tb IIIC T□1) Db IP66
    □1) See Selection table, P19

    Ex-mark (ATEX)

    II 2 G Ex db IIB+H2 T□1) Gb
    II 2 D Ex tb IIIC T□1) Db IP66
    □1) See Selection table, P19

    Certificates

    IECEx; ATEX

    Conformity to standards

    EN 60079-0, EN 60079-1, EN 60079-11, EN 60079-31
    IEC 60079-0, IEC 60079-1, IEC 60079-11, IEC 60079-31

    Enclosure material

    Copper-free Aluminium Alloy enclosure, powder coated surface, window grey (RAL7040)

    Exposed fastener

    Stainless steel

    Built-in components

    Ammeters, voltmeters, power meters, tachometers temperature control meters and other meters, control switches, disconnecting switches, Moulded Case Circuit Breakers (MCCB), Miniature Circuit Breakers(MCB), AC contactors, thermal relays, intermediate relays, time relays, control transformers, DC power supplies, current transformers, surge protectors, PLCs, fuses, soft starters, frequency converters, terminals, bus bars, resistors, light-operated switches, time controllers, optical fiber control boxes, magnet valves, analytical instruments, heaters, self-regulation trace heating cables, display screens, magnetic ballasts of HID light sources, electronic ballasts of fluorescent lamps, drivers of LED light sources, emergency devices of HID light sources, emergency devices of fluorescent lamps, emergency devices of LED light sources, safety barriers, integrated protectors of motors, lighting building controllers, lighting energy saving controllers, fire monitoring controllers, temperature controllers, humidity controllers, current monitors, voltage monitors, motor protection switches, dual power transfer switches, counters, timers, solid state relays, diode modules, industrial personal computers, UPS, batteries.

    Rated voltage

    Max. 660V AC 50/60Hz Max. 1000V DC

    Rated current

    Max. 630A

    Degree of protection

    IP66

    Internal & external earthing

    M6/M8, M8/M8

    Ambient temperature

    -40℃~+60℃

    Cable entries

    Standard M□x 1.5 plug (the size of entry hole should be processed in accordance with actual requirements), NPT□plug on request.

    Cable gland (optional)

     

    Entry direction

    Bottom

    Mounting

    Surface type (standard)
    Pedestal type (optional)

     

    See table for max. dissipated power

    Ta=60℃

    KXD51 with metal cover without glass

    T4(T130℃)

    T5(T95℃)

    T6(T80℃)

    Type

    Power (W)

    T Rise (K)

    Power (W)

    T Rise (K)

    Power (W)

    T Rise (K)

    KXD51-Ⅰ

    200

    70

    80

    33

    38

    17

    KXD51-Ⅱ

    200

    65

    80

    31

    40

    17

    KXD51-ⅡB

    240

    67

    100

    31

    50

    17

    KXD51-Ⅲ

    290

    66

    130

    32

    60

    17

    KXD51-ⅢB

    350

    67

    140

    32

    75

    17

    KXD51-Ⅳ

    420

    62

    190

    33

    100

    17

    KXD51-ⅣB

    500

    65

    210

    34

    100

    17

    KXD51-Ⅴ

    520

    60

    240

    31

    125

    17

    KXD51-ⅤB

    620

    61

    280

    31

    140

    17

    KXD51-Ⅵ

    660

    61

    300

    31

    150

    17

    KXD51-ⅥB

    660

    53

    330

    31

    180

    17

    KXD51-Ⅶ

    700

    50

    400

    28

    210

    17

    KXD51-ⅦB

    700

    49

    400

    27

    220

    17

     

    Ta=60℃

    KXD51 with metal cover with glass

    T4(T130℃)

    T5(T95℃)

    T6(T80℃)

    Type

    Power (W)

    T Rise (K)

    Power (W)

    T Rise (K)

    Power (W)

    T Rise (K)

    KXD51-Ⅰ

    170

    69

    70

    33

    38

    17

    KXD51-Ⅱ

    170

    69

    70

    33

    38

    17

    KXD51-ⅡB

    200

    69

    80

    33

    38

    17

    KXD51-Ⅲ

    260

    66

    110

    33

    55

    17

    KXD51-ⅢB

    320

    67

    120

    31

    65

    17

    KXD51-Ⅳ

    380

    69

    160

    35

    72

    17

    KXD51-ⅣB

    425

    68

    170

    34

    81

    17

    KXD51-Ⅴ

    450

    66

    200

    34

    90

    17

    KXD51-ⅤB

    540

    66

    220

    34

    100

    17

    KXD51-Ⅵ

    620

    70

    260

    34

    140

    17

    KXD51-ⅥB

    660

    58

    330

    34

    170

    17

    KXD51-Ⅶ

    700

    56

    400

    32

    185

    17

    KXD51-ⅦB

    700

    56

    400

    32

    190

    17

     

    Dimension drawings (all dimensions in mm) - subject to alteration

    Version

    External dimension

    Internal dimension

    Mounting dimension

    Weight of
    enclosure
    (kg)

    A

    B

    C

    a

    b

    c

    D

    E

    F

    KXD51-Ⅰ

    250

    200

    170

    192

    142

    131

    180

    200

    10

    6.70

    KXD51-Ⅱ

    300

    200

    170

    242

    142

    131

    230

    200

    10

    8.00

    KXD51-ⅡB

    350

    200

    170

    292

    142

    131

    280

    200

    10

    9.50

    KXD51-Ⅲ

    350

    300

    200

    290

    240

    159

    280

    300

    12

    14.50

    KXD51-ⅢB

    350

    300

    270

    290

    240

    229

    280

    300

    12

    17.50

    KXD51-Ⅳ

    450

    350

    210

    378

    278

    163

    365

    350

    12

    23.00

    KXD51-ⅣB

    450

    350

    280

    378

    278

    233

    365

    350

    12

    27.50

    KXD51-Ⅴ

    560

    400

    210

    488

    328

    115

    475

    400

    14

    34.50

    KXD51-ⅤB

    560

    400

    280

    488

    328

    225

    475

    400

    14

    39.50

    KXD51-Ⅵ

    634

    434

    265

    560

    360

    205

    522

    430

    14

    46.00

    KXD51-ⅥB

    634

    434

    335

    560

    360

    275

    522

    430

    14

    52.00

    KXD51-Ⅶ

    720

    560

    275

    640

    480

    215

    620

    560

    14

    74.50

    KXD51-ⅦB

    720

    560

    345

    640

    480

    285

    620

    560

    14

    83.00

    Note:
    For cable entries:
    1). Please specify the direction and size of each cable entry.
    2). Cable gland is optional.

     

    KXD51 Explosion-proof distribution panels for terminal box use

    Suitable for terminal boxes of distribution system

    Note:

    1. KXD51-J terminal boxes have various different terminal arrangement methods.

    2. It can be customized in accordance with user’s requirements and conforms to the usage limits of conformity certificate. The Max. number of terminals and the Max. number of holes on side can meet the requirements of dissipated power and enclosure mechanical strength.

    3. This table is only for reference.

     

    KXD51 Explosion-proof distribution panels for distribution box use

    Suitable for power units of distribution system

    Note:

    1. MCB (Miniature Circuit Breaker) or MCCB (Moulded Case Circuit Breaker), AC contactor, thermal overload relay, PLC programmer, soft starter, pushbuttons, indicators, control switches and explosion-proof ammeters/voltmeters etc. in KXD51-P distribution boxes.

    2. KXD51-P power unit can be used for distribution or on-off of circuit. It also can be used for controlling the start, stop, corotation and inversion of motor and provide comprehensive protection for motor. It can be equipped with two-site control or multi-site control.

    3. It can be customized in accordance with user’s requirements and conforms to the usage limits of conformity certificate. The number of cover components and the Max. number of holes on side can meet the requirements of dissipated power and enclosure mechanical strength.

     

    KXD51 Explosion-proof Distribution panels for control box use

    Suitable for control unit of distribution system

    Note:

    1. pushbuttons, indicators, control switches and explosion-proof ammeters / voltmeters etc. in KXD51-K control boxes.

    2. KXD51-K control box can be used for on-off operation of circuit. It also can realize the remote control or local control of the start, stop, corotation and inversion of motor. When it is equipped with ammeter, it also can monitor the running of motor and circuit status.

    3. It can be customized in accordance with user’s requirements and conforms to the usage limits of conformity certificate. The number of cover components and the Max. number of holes on side can meet the requirements of dissipated power and enclosure mechanical strength.

     

    Typical scheme diagram

Keyword:


Product Inquiry


Please contact us in time to get your exclusive discount.