Explosion-proof Distribution Device
KXD61 Series
Category:
Explosion-proof Distribution Device
- 产品描述
-
CATALOG NUMBER LOGIC

FEATURES
- Flameproof enclosure (Ex d IIB+H2), which can be used as feed distribution equipment in control and distribution system(such as distribution box, switch box of main circuit ,control box, terminal box or motor starting box etc.)
- Enclosure: stainless steel.
- Equipped with specialized hinge structure, which can prevent the flameproof joints from damage when opening and closing the panels, and greatly prolong the service life of box.
- The boxes can be combined and installed freely to save space and meet the requirements of various distribution systems.
- Special requirements on request.
Application sectors

TECHNICAL DATA
Explosion-proof Distribution Device KXD61 - □ / □ / □ / □
Ex-mark (IECEx)
Where the Spec. type is: I, II, IIB ... VIIB
Ex db IIB+H2 T□1) Gb
Ex tb IIIC T□1) Db IP66
Where the Spec. type is: VIII, VIIIB, IX, IXB
Ex db IIB T□1) Gb
Ex tb IIIC T□1) Db IP66
□1) See Selection table, P29Ex-mark (ATEX)
Where the Spec. type is: I, II, IIB ... VIIB
II 2 G Ex db IIB+H2 T□1) Gb
II 2 D Ex tb IIIC T□1) Db IP66
Where the Spec. type is: VIII, VIIIB, IX, IXB
II 2 G Ex db IIB T□1) Gb
II 2 D Ex tb IIIC T□1) Db IP66
□1) See Selection table, P29Certificates
IECEx; ATEX
Conformity to standards
EN 60079-0, EN 60079-1, EN 60079-11, EN 60079-31
IEC 60079-0, IEC 60079-1, IEC 60079-11, IEC 60079-31Enclosure material
Stainless steel
Exposed fastener
Stainless steel
Built-in components
Ammeters, voltmeters, power meters, tachometers temperature control meters and other meters, control switches, disconnecting switches, Moulded Case Circuit Breakers (MCCB), Miniature Circuit Breakers(MCB), AC contactors, thermal relays, intermediate relays, time relays, control transformers, DC power supplies, current transformers, surge protectors, PLCs, fuses, soft starters, frequency converters, terminals, bus bars, resistors, light-operated switches, time controllers, optical fiber control boxes, magnet valves, analytical instruments, heaters, self-regulation trace heating cables, display screens, magnetic ballasts of HID light sources, electronic ballasts of fluorescent lamps, drivers of LED light sources, emergency devices of HID light sources, emergency devices of fluorescent lamps, emergency devices of LED light sources, safety barriers, integrated protectors of motors, lighting building controllers, lighting energy saving controllers, fire monitoring controllers, temperature controllers, humidity controllers, current monitors, voltage monitors, motor protection switches, dual power transfer switches, counters, timers, solid state relays, diode modules, industrial personal computers, UPS, batteries.
Rated voltage
Max. 1000V AC 50/60Hz Max. 1500V DC
Rated current
Max. 2000A
Degree of protection
IP66
Internal & external earthing
M6/M8, M8/M8
Ambient temperature
-40℃~+60℃
Cable entries
Standard M□x 1.5 plug (the size of entry hole should be processed in accordance with actual requirements), NPT□plug on request.
Cable gland (optional)
Entry direction
Bottom
Mounting
Surface type (standard)
Pedestal type (optional)See table for max. dissipated power
Ta=60
KXD61 with metal cover without glass
T4(T130℃)
T5(T95℃)
T6(T80℃)
Type
Power (W)
T Rise (K)
Power (W)
T Rise (K)
Power (W)
T Rise (K)
KXD61-Ⅰ
101
70
51
35
22
17
KXD61-Ⅱ
101
70
51
35
25
17
KXD61-ⅡB
101
70
51
35
25
17
KXD61-Ⅲ
145
70
73
35
31
17
KXD61-ⅢB
168
70
84
35
41
17
KXD61-Ⅳ
148
70
74
35
36
17
KXD61-ⅣB
188
70
94
35
46
17
KXD61-Ⅴ
190
70
95
35
40
17
KXD61-ⅤB
239
70
119
35
56
17
KXD61-Ⅵ
279
70
139
35
55
17
KXD61-ⅥB
288
70
144
35
70
17
KXD61-Ⅶ
279
70
139
35
55
17
KXD61-ⅦB
299
70
149
35
72
17
KXD61-Ⅷ
686
70
343
35
167
17
KXD61-ⅧB
743
70
371
35
180
17
KXD61-Ⅸ
975
70
488
35
237
17
KXD61-ⅨB
1149
70
575
35
279
17
Ta=60
KXD61 with metal cover with glass
T4(T130℃)
T5(T95℃)
T6(T80℃)
Type
Power (W)
T Rise (K)
Power (W)
T Rise (K)
Power (W)
T Rise (K)
KXD61-Ⅰ
101
70
51
35
19
17
KXD61-Ⅱ
101
70
51
35
20
17
KXD61-ⅡB
129
70
65
35
26
17
KXD61-Ⅲ
150
70
75
35
31
17
KXD61-ⅢB
155
70
77
35
38
17
KXD61-Ⅳ
215
70
108
35
38
17
KXD61-ⅣB
224
70
112
35
49
17
KXD61-Ⅴ
187
70
93
35
37
17
KXD61-ⅤB
251
70
125
35
61
17
KXD61-Ⅵ
266
70
133
35
71
17
KXD61-ⅥB
319
70
160
35
79
17
KXD61-Ⅶ
290
70
145
35
71
17
KXD61-ⅦB
313
70
157
35
76
17
KXD61-Ⅷ
709
70
354
35
172
17
KXD61-ⅧB
780
70
390
35
189
17
KXD61-Ⅸ
953
70
476
35
231
17
KXD61-ⅨB
1206
70
603
35
293
17
Dimension drawings (all dimensions in mm) - subject to alteration

Version
External dimension
Internal dimension
Mounting dimension
Weight of
enclosure
(kg)A
B
C
a
b
c
D
E
F
KXD61-Ⅰ
250
200
170
192
142
135
150
180
9
15.30
KXD61-Ⅱ
300
200
170
242
142
135
200
180
10
17.70
KXD61-ⅡB
350
200
170
292
142
135
250
180
10
20.10
KXD61-Ⅲ
350
300
200
292
242
168
250
290
10
28.70
KXD61-ⅢB
350
300
270
292
242
238
250
290
10
31.80
KXD61-Ⅳ
450
350
210
362
262
163
330
318
10
44.80
KXD61-ⅣB
450
350
280
362
262
233
330
318
10
49.40
KXD61-Ⅴ
560
400
210
468
308
163
420
370
14
68.30
KXD61-ⅤB
560
400
280
468
308
233
420
370
14
73.80
KXD61-Ⅵ
634
434
265
542
342
218
494
404
14
103.50
KXD61-ⅥB
634
434
335
542
342
288
494
404
14
112.80
KXD61-Ⅶ
720
560
275
628
468
228
580
530
14
156.10
KXD61-ⅦB
720
560
345
628
468
298
580
530
14
169.30
KXD61-Ⅷ
980
720
325
884
624
272
840
690
14
329.40
KXD61-ⅧB
980
720
425
884
624
372
840
690
14
354.90
KXD61-Ⅸ
1280
900
350
1184
804
297
1140
870
14
589.80
KXD61-ⅨB
1280
900
500
1184
804
447
1140
870
14
655.90
Note:
For cable entries:
1). Please specify the direction and size of each cable entry.
2). Cable gland is optional.KXD61 Explosion-proof distribution panels for terminal box use
Suitable for terminal boxes of distribution system
Note:
1. KXD61-J terminal boxes have various different terminal arrangement methods.
2. It can be customized in accordance with user's requirements and conforms to the usage limits of conformity certificate. The Max. number of terminals and the Max. number of holes on side can meet the requirements of dissipated power and enclosure mechanical strength.
3. This table is only for reference.

KXD61 Explosion-proof distribution panels for distribution box use
Suitable for power units of distribution system
Note:
1. MCB (Miniature Circuit Breaker) or MCCB (Moulded Case Circuit Breaker), AC contactor, thermal overload relay, PLC programmer, soft starter, pushbuttons, indicators, control switches and explosion-proof ammeters/voltmeters etc. in KXD61-P distribution boxes.
2. KXD61-P power unit can be used for distribution or on-off of circuit. It also can be used for controlling the start, stop, corotation and inversion of motor and provide comprehensive protection for motor. It can be equipped with two-site control or multi-site control.
3. It can be customized in accordance with user's requirements and conforms to the usage limits of conformity certificate. The number of cover components and the Max. number of holes on side can meet the requirements of dissipated power and enclosure mechanical strength.

KXD61 Explosion-proof Distribution panels for control box use
Suitable for control unit of distribution system
Note:
1. pushbuttons, indicators, control switches and explosion-proof ammeters / voltmeters etc.in KXD61-K control boxes.
2. KXD61-K control box can be used for on-off operation of circuit. It also can realize the remote control or local control of the start, stop, corotation and inversion of motor. When it is equipped with ammeter, it also can monitor the running of motor and circuit status.
3. It can be customized in accordance with user's requirements and conforms to the usage limits of conformity certificate. The number of cover components and the Max. number of holes on side can meet the requirements of dissipated power and enclosure mechanical strength.

Typical scheme diagram




Keyword:
KXD51 Series
Explosion-proof Distribution Device
KXD61 Series
Explosion-proof Distribution Device
KXD53-J Series
Explosion-proof Terminal Boxes
Product Inquiry
Please contact us in time to get your exclusive discount.